154
CET Electric Technology
109
Return Value (x1000)
Mains kvar Total H Alarm Return
110
Return Value (x1000)
Mains kvar Total L Alarm Return
111
Return Value (x1000)
Mains kVA Total H Alarm Return
112
Return Value (x1000)
Mains kVA Total L Alarm Return
113
Return Value (x1000)
Mains PF Total H Alarm Return
114
Return Value (x1000)
Mains PF Total L Alarm Return
115
Return Value (x1000)
Current Demand HH Alarm Return
116
Return Value (x1000)
Current Demand H Alarm Return
117
Return Value (x1000)
Current Demand L Alarm Return
118
Return Value (x1000)
Current Demand LL Alarm Return
119
Return Value (x1000)
Mains kW Total Demand H Alarm Return
120
Return Value (x1000)
Mains kW Total Demand L Alarm Return
121
Return Value (x1000)
Mains kvar Total Demand H Alarm Return
122
Return Value (x1000)
Mains kvar Total Demand L Alarm Return
123
Return Value (x1000)
Mains kVA Total Demand H Alarm Return
124
Return Value (x1000)
Mains kVA Total Demand L Alarm Return
125
Return Value (x100)
Frequency H Alarm Return
126
Return Value (x100)
Frequency L Alarm Return
127
Return Value (x100)
Voltage Unbalance Alarm Return
128
Return Value (x100)
Voltage Unbalance Alarm Return
129
Return Value (x100)
Mains THD Alarm Return
130
Return Value (x100)
Mains TOHD Alarm Return
131
Return Value (x100)
Mains TEHD Alarm Return
132
Return Value (x10)
Temperature HH Alarm Return
133
Return Value (x10)
Temperature H Alarm Return
134
Return Value
DI Status Change Alarm Return
135
Return Value
Phase Reversal Alarm Return
136
Return Value
Phase Loss Alarm Return
137
Return Value
3
Dip Alarm Return
138
Return Value
3
Swell Alarm Return
139
Return Value
3
Interruption Alarm Return
3
1
0
Method
0: Modbus
1: Web
2: Reset Button
Power On
2
0
Power Off
3
0
Set Time
4
0
Set System Parameters
5
0
Set Names for Panels, SMs or VMs
6
0
Set Communication Parameters
7
0
Set Breaker Ratings
8
0
Set Alarm Parameters
9
0
Set Calibration Parameters
10
0
Set Factory Parameters
11
0
Set Branch Parameters
12
0
Set Total VM Parameters
13
0
Set DR Parameters
14
0
Set SM Customization Parameters
15
0
Reset Alarm
16
0
Clear Alarm Counter
17
0
Clear Energy
18
0
Clear Max Demand Logs
19
0
Clear SOE
20
0
Clear Max/Min Logs
21
0
Clear WFR
22
0
Clear IER Logs
23
0
Manually Trigger WFR
24
0
Preset Energy
25
0-9, 0xFF
Clear DR Log
26-29
-
Reserved
30
Parameter
Type²
Load Factory Default Configuration
31
0
Clear All Recorder
32
0
Formatting Ferroelectric
33
0
Formatting the Disk
34
0
Importing Configuration Files
35
0
Exporting the Ferroelectric Memory
36
0
Importing the Ferroelectric Memory
4
1
0
0
NVRM Fault