6. Mount the 3 micro switches to the shift
box assembly using the specified hard
-
ware. Two are mounted to the right and
1 is mounted to the left.
Connect the
green jumper cable between the two sides
to link the switches for the neutral safety
feature
. Photo TR-392
TR-392
Connecting the Shift Cables to the Shifter
Box
When connecting the 2 shift cables to the shift box, be sure to connect the Reverse shift
cable and the High and Low shift cable to the correct side of the shift box assembly. Refer
to the
IMPORTANT
note on page TR-66 of this manual for further details.
You will need to peel back the protective covering from the threaded end of the cable to al
-
low the mounting nuts to be threaded on and off.
Photo TR-393
7. Insert the cable to the shifter box and
secure with the nut.
Photo TR-394
Generally when securing the cable to the
box, an even amount of threads to the inside
and outside of the box is a good initial start-
ing point. See photo TR-378 on page TR-70.
There may be some minor adjustments later.
TR-393
Summary of Contents for 2001 950
Page 2: ......
Page 4: ......
Page 353: ......
Page 413: ......
Page 416: ...saue Axial Piston Pumps Motors and Transmissions Technical Information Series 70 15 Series ...
Page 429: ...14 saue Axial Piston Pumps Motors and Transmissions Series 70 15 Series Notes ...
Page 447: ...31 saue Axial Piston Pumps Motors and Transmissions Series 70 15 Series Notes ...
Page 449: ......