CHAPTER 13 TROUBLESHOOTING
37
E700
Cause
DC power supply
PCB
CPU PCB
Action
Check the wiring; if
normal, replace the DC
power supply PCB.
Replace the CPU PCB.
(After replacment,
execute the work under
II. H. 1.)
Step
1
Yes/No
NO
YES
Checks
Is power present at J2010 on the
CPU PCB?
38
E717
Cause
Service mode
Connection
Copy data/remote
diagnostic device
controller PCB,
CPU PCB
Action
Disconnect it after
executing service mode.
Connect the connectors
properly.
Try replacing the
following parts in turns:
• copy data/remote
diagnostic device PCB
• CPU PCB
(After replacement,
execute the work
under II. H. 1.)
Step
1
2
Yes/No
NO
YES
NO
Checks
Has the copy data/remote
diagnostic device been
disconnected from the copier after
executing
COPIER>OPTION>INIT-
FACE>B-CLR?
Is there a fault in the connection
between the copier and the copy
data/remote diagnosis device?
Voltage
+5V
-8V
+8.8V
+24V
+15V
(+)
J2010-2
J2010-3
J2010-5
J2010-7
J2010-9
(-)
J2010-1
J2010-4
J2010-4
J2010-6
J2010-8
Summary of Contents for CLC 1130
Page 8: ......
Page 24: ......
Page 26: ......
Page 33: ......
Page 55: ......
Page 101: ......
Page 103: ......
Page 121: ......
Page 141: ......
Page 143: ......
Page 159: ......
Page 239: ......
Page 247: ......
Page 255: ......
Page 261: ......
Page 263: ......
Page 369: ......
Page 397: ......
Page 399: ......
Page 451: ......
Page 453: ......
Page 493: ......
Page 495: ......
Page 549: ......
Page 556: ......
Page 563: ......
Page 586: ......
Page 670: ......
Page 674: ......
Page 683: ......
Page 698: ......
Page 704: ......
Page 711: ......
Page 785: ......
Page 799: ......
Page 829: ......
Page 945: ......
Page 957: ......
Page 959: ......
Page 963: ......