[4]
[5]
5. Adjusting the Pressure of the
Separation Roller
1) Remove the two screws [2] and detection
lower guide [1].
Figure 7-711
2) Remove the paper guide [3].
Figure 7-712
3) Remove the two screws [4], and detach
the separation roller assembly [5].
Figure 7-713
[1]
[2]
[2]
[3]