COPYRIGHT © 2002 CANON INC. CANON CLC1100/1130/1150/1160/1180 REV.2 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
13-85
CHAPTER 13 TROUBLESHOOTING
12
The copy has a fixing fault.
Cause
Fixing upper/
lower roller
Fixing heater
Oil applying
mechanism
Insulating bush,
bearing
Nip
Thermistor
Action
1. Check the upper
roller and the lower
roller of the fixing
assembly for
scratches.
2. Check the separation
claws to see if they
are mounted
properly.
See
IV. 54.
.
• Check the oil applying
assembly.
• Check the mechanism
used to supply oil
from the oil case.
Mount the parts
properly.
Adjust the nip.
Check the thermistor for
a fault.
Step
1
2
3
4
5
Yes/No
YES
NO
NO
NO
NO
YES
Checks
Is the problem noted in paper
feeding direction?
Does the heater (H1, H2) turn on
immediately after power-on?
Is the upper roller of the fixing
assembly coated with a uniform
layer of oil?
Are the insulating bush and the
bearing mounted properly?
Is the nip of the upper roller and
the lower roller of the fixing
assembly as indicated?
Summary of Contents for CLC 1130
Page 8: ......
Page 24: ......
Page 26: ......
Page 33: ......
Page 55: ......
Page 101: ......
Page 103: ......
Page 121: ......
Page 141: ......
Page 143: ......
Page 159: ......
Page 239: ......
Page 247: ......
Page 255: ......
Page 261: ......
Page 263: ......
Page 369: ......
Page 397: ......
Page 399: ......
Page 451: ......
Page 453: ......
Page 493: ......
Page 495: ......
Page 549: ......
Page 556: ......
Page 563: ......
Page 586: ......
Page 670: ......
Page 674: ......
Page 683: ......
Page 698: ......
Page 704: ......
Page 711: ......
Page 785: ......
Page 799: ......
Page 829: ......
Page 945: ......
Page 957: ......
Page 959: ......
Page 963: ......