6) Mount the black toner concentration
sensor unit, and connect the connector
with a screw.
•
During insertion, take care not to make
contact with the photosensitive drum.
If the No. 2 blade comes
into contact with the
photosensitive drum during
insertion, lubricant can
spread to the photosensitive
drum, causing white spots
in copy images.
7) Remove the screw, and pull the
photosensitive drum cleaner to the front;
then, shift it counterclockwise, and then
slide it out.
Figure 11-218
Screw
Photosensitive drum cleaner