CHAPTER 13 TROUBLESHOOTING
13-60
COPYRIGHT © 2002 CANON INC. CANON CLC1100/1130/1150/1160/1180 REV.1 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
5. 16-Gradation Test Print (PG>TYPE=4)
Use a 16-gradation test print to check gradation, fogging, white lines, uneven density between
left and right, and balance of colors.
a.
Gradation
If density graduation in 16 gradations is not noted as shown, suspect a fault in the laser system.
b.
Fogging
If fogging is noted in the white area of the figure, suspect a fault in the developing system or the
photosensitive drum or wrong adjustment of the laser.
c.
White Lines
If white lines are noted in images, suspect a fault in the developing system.
d.
Uneven Density between Left and Right
If uneven density is noted between left and right, suspect dirt on the developing roller, dirt on
the butting block, and a fault in the height of the primary charging wire.
You can generate a printout of each color using COPIER>TEST>PG of service
mode and selecting the following: COLOR-Y, COLOR-M, COLOR-C,
COLOR-K.
Figure 13-306 COLOR-M Set to '1'
16-g
radation
White
Summary of Contents for CLC 1130
Page 8: ......
Page 24: ......
Page 26: ......
Page 33: ......
Page 55: ......
Page 101: ......
Page 103: ......
Page 121: ......
Page 141: ......
Page 143: ......
Page 159: ......
Page 239: ......
Page 247: ......
Page 255: ......
Page 261: ......
Page 263: ......
Page 369: ......
Page 397: ......
Page 399: ......
Page 451: ......
Page 453: ......
Page 493: ......
Page 495: ......
Page 549: ......
Page 556: ......
Page 563: ......
Page 586: ......
Page 670: ......
Page 674: ......
Page 683: ......
Page 698: ......
Page 704: ......
Page 711: ......
Page 785: ......
Page 799: ......
Page 829: ......
Page 945: ......
Page 957: ......
Page 959: ......
Page 963: ......