CHAPTER 13 TROUBLESHOOTING
13-132
COPYRIGHT © 2002 CANON INC. CANON CLC1100/1130/1150/1160/1180 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
Cause
Wiring, DC load
DC fuse PCB
Action
Check the wiring from
the DC fuse PCB to the
DC loads. Check the DC
loads.
Replace the DC fuse
PCB.
Step
4
Yes/No
YES
NO
Checks
Connect all connectors of the DC
power supply PCB. Is the voltage
of the connectors shown in the
following table normal?
Connector
J906
J907
J908
J909
J910
J931
J932
J933
J934
J935
J936
J937
Pin
3, 4
4 to 6
6 to 10
5to8
2
4 to 6
4 to 7
5 to 7
6 to 9
3, 4
5 to 8
2, 4
Output
5V
5V
5V
5V
5V
24V
24V
24V
24V
24V
24V
38V
Summary of Contents for CLC 1130