CHAPTER 6 IMAGE FORMATION SYSTEM
6-24
COPYRIGHT © 2002 CANON INC. CANON CLC1100/1130/1150/1160/1180 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
F. Controlling the Post-Cleaning Charging Current
1. Operations
The post-cleaning charging mechanism has the following items of control:
1. Controlling the static eliminating charge to a constant current level.
Each of the signals is used for the following:
[1] HVCC (post-cleaning charge ON/OFF control signal)
When ‘1’, the high-voltage output is ready.
[2] HVCI (post-cleaning charge level control signal)
Controlled to +3 to +11 V; at +11 V or less, the high-voltage output is generated.
Figure 6-306
[1]
[2]
J1012
-A8
J411
-6
T302
HVCC
HVCI
-A7
-7
DC driver PCB
HVT-DC PCB
Post-cleaning
charge