CHAPTER 13 TROUBLESHOOTING
13-40
COPYRIGHT © 2002 CANON INC. CANON CLC1100/1130/1150/1160/1180 REV.1 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
9) Press the Reset key, and turn off the power switch.
10) Disconnect the connector J1 of the environment measurement PCB.
11) Turn on the power switch.
12) Check the temperature and the humidity on the DISPLAY>ANALOG screen in service mode.
TEMP:
25 ±5°C
ABS-HUM: 36 ±10%
13) Check to see that the reading is as indicated.
If not, suspect a fault on the DC driver PCB or the CPU PCB.
14) Press the Reset key.
15) Turn off the power switch.
16) Connect the connector J1 to the environment measurement PCB.
17) Detach the environment measurement PCB checker from the environment measurement PCB,
and connect the environment sensor in its place.
18) Attach all covers.
b. Checking the Environment Sensor
1) Check the environment measurement PCB.
2) Turn on the power switch, and leave the copier alone for 5 min.
3) Check the temperature and the humidity on the DISPLAY>ANALOG screen in service mode,
and record the readings. (data A)
TEMP:
°C
data A1
ABS-HUM:
%
data A2
4) Press the Reset key, and turn off the power switch.
5) Detach the environment sensor from the environment measurement PCB, and insert the
environment sensor calibration tool (TKN-0456) in its place.
6) Turn on the power switch, and leave the copier alone for 5 min.
7) Check the temperature and the humidity on the DISPLAY>ANALOG screen in service mode,
and take notes of them.
TEMP:
°C
data B1
ABS-HUM:
%
data B2
8) Compare data A and data B.
•
difference between data A1 and data B1 is 0 ± 5.
•
difference between data A2 and data B2 is 0 ± 20
If the difference between data A and data B is not as indicated, replace the environment sensor.
9) Press the Reset key, and turn off the power switch.
10) Detach the environment sensor calibrating tool from the environment measurement PCB, and
fit the environment sensor.
11) Mount all covers.
The environment sensor calibration tool (TN-0456) is adjusted at the factory to
high precision. Be sure to store it in an airtight container with a drying agent for
storage.
Summary of Contents for CLC 1130
Page 8: ......
Page 24: ......
Page 26: ......
Page 33: ......
Page 55: ......
Page 101: ......
Page 103: ......
Page 121: ......
Page 141: ......
Page 143: ......
Page 159: ......
Page 239: ......
Page 247: ......
Page 255: ......
Page 261: ......
Page 263: ......
Page 369: ......
Page 397: ......
Page 399: ......
Page 451: ......
Page 453: ......
Page 493: ......
Page 495: ......
Page 549: ......
Page 556: ......
Page 563: ......
Page 586: ......
Page 670: ......
Page 674: ......
Page 683: ......
Page 698: ......
Page 704: ......
Page 711: ......
Page 785: ......
Page 799: ......
Page 829: ......
Page 945: ......
Page 957: ......
Page 959: ......
Page 963: ......