xGenConnect Installation and Programming Guide
The heartbeat interval is set to 1800 seconds (30 min) and is sent to OH,
port 8799.
The LAN fault delay is set to 90 seconds. In case a LAN failure occurs and is
restored within 90 seconds, the LAN fault message will not be reported to OH.
If the fault remains present for a longer period, the LAN fault message will be
reported after 90 seconds.
The Cellular fault delay is set to 180 seconds. In case a cellular failure occurs
and is restored within 180 seconds, the cellular fault message will not be
reported to OH. If the fault remains present for a longer period, the LAN fault
message will be reported after 180 seconds.
Enabling Push Notifications on Smartphone
Smartphones with the Ul app can receive push notifications from the
panel when system events occur.
You will need to have a:
• Fully configured and online xGenConnect system.
• Fully configured smartphone with internet access and Apple / Google account
details. This must be signed into the relevant Apple ID / Google account so
their servers can deliver the message to the device.
1. Open the Ul app.
2. Click the edit button next to the site you wish to receive notifications from.
Summary of Contents for xGenConnect
Page 1: ...xGenConnect Installation and Programming Guide P N 466 5545 EN REV J ISS 26OCT22...
Page 4: ......
Page 12: ...viii xGenConnect Installation and Programming Guide...
Page 93: ...xGenConnect Installation and Programming Guide 81 Web Page...
Page 109: ...xGenConnect Installation and Programming Guide 97 Instructions 1 Go to Zone Type...
Page 117: ...xGenConnect Installation and Programming Guide 105 Webpage...
Page 156: ...144 xGenConnect Installation and Programming Guide...
Page 166: ...154 xGenConnect Installation and Programming Guide...