xGenConnect Installation and Programming Guide
5
Zone Doubling
3.74 kΩ / 6.98 kΩ
See “Detector EOL Wiring” on page 23 for more
information.
Onboard outputs:
NXG-4
4: bell, strobe, siren and power outputs
NXG-8(E), NXG-9
5: bell, strobe, siren and power outputs
Maximum output number
32
Maximum action number
32
Partitions:
NXG-4
4
NXG-8(E), NXG-9
8
Maximum keypad:
NXG-4
16
NXG-8(E), NXG-9
24
Maximum expander modules, incl. keypads:
NXG-4
24
NXG-8(E), NXG-9
32
Non-volatile Memory
Main event log capacity
1024
Access event log capacity
5000
Data retention (log, program settings)
10 years
Ethernet Connection (IP only)
Supported standard
IEEE 802.3u
Speed
10BASE-T or 100BASE-TX
Duplex
Half-duplex and full-duplex
Cabling
FTP (foiled twisted pair) Cat 5e cable or better
xGenConnect Bus
Type
4 wire RS485 bus
High common mode tolerance (25V)
Capacity
Up to 32 devices
Range
800 m
Cable flammability rating
VW-1
Current Consumption
Product
Main description
Current Consumption
(non-alarm)
Current
Consumption (alarm)
NXG-8(E)
8 zone panel
125 mA typical
125 mA typical
NXG-9
8 zone panel
150 mA typical
150 mA typical
NXG-4
4 zone panel
140 mA typical
140 mA typical
Summary of Contents for xGenConnect
Page 1: ...xGenConnect Installation and Programming Guide P N 466 5545 EN REV J ISS 26OCT22...
Page 4: ......
Page 12: ...viii xGenConnect Installation and Programming Guide...
Page 93: ...xGenConnect Installation and Programming Guide 81 Web Page...
Page 109: ...xGenConnect Installation and Programming Guide 97 Instructions 1 Go to Zone Type...
Page 117: ...xGenConnect Installation and Programming Guide 105 Webpage...
Page 156: ...144 xGenConnect Installation and Programming Guide...
Page 166: ...154 xGenConnect Installation and Programming Guide...