xGenConnect Installation and Programming Guide
19
NXG-8(E) Terminals
LAN-, LAN+, NEG, POS: Terminals for xGenConnect
RS485 bus.
LEARN: Enrollment button, hold down for 3 s to activate
automatic device enrollment feature.
TERM: Term link for xGenConnect RS485 bus. A TERM
link should be installed on the two furthest devices.
EARTH, AC, AC: Connect transformer (16 VAC 1.5 A) to
terminals for power.
−BLACK, +RED: Connect leads to 12V Sealed Lead Acid
backup battery.
BELL+, BELL
−: Connect to indoor 12 VDC siren or
speaker.
DATA, COM, POS: NetworX 3-wire bus for legacy
modules and keypads.
SMOKE-, AUX+: Two or four wire smoke detectors, NXG-
8 supports two wire smoke detectors and will drop
power to the SMOKE- terminal to perform smoke
alarm verification.
COM, AUX+: Terminal for aux power to zones.
ZONE 1 to 8, COM
– terminals to connect to zones.
Supports single EOL, zone doubling, and dual EOL
tamper monitoring.
J14: Ethernet WAN link header must be fitted if no
communicator module is installed, and must be
removed to accommodate communicator module.
J11: Terminal to connect communicator module to
xGenConnect.
Ethernet: Connect Ethernet cable to RJ45 socket to
provide internet connectivity to xGenConnect.
J13: 5-pin connector used to upgrade and program
xGenConnect with USBUP-EUR-V2 tool.
TAMPER: Connect to panel box tamper.
AUX+: Terminal for auxiliary power to outputs.
OUTPUT 4: Open collector output switches to ground,
power output, by default inverted, can be assigned to
an Action.
OUTPUT 3: Open collector output switches to ground,
power output, by default inverted, can be assigned to
an Action.
OUTPUT 2: Open collector output switches to ground,
hold-off for outdoor siren, by default inverted, can be
assigned to an Action.
OUTPUT 1: Open collector output switches to ground,
hold-off for outdoor flash, by default inverted, can be
assigned to an Action.
Z WAVE
XGEN
LAN
TERM
LEARN
BUS
12 V 7 Ah
NXG-7002(-SIM)
J14
USBUP
TAMPER
ETHERNET
LAN
−
OUTPUT 2
−
OUTPUT 3
−
OUTPUT 4−
AUX+
ZONE 1
COM
ZONE 3
ZONE 4
ZONE 5
COM
ZONE 6
ZONE 7
COM
ZONE 8
AUX+
COM
SMOKE−
POS
COM
DATA
BELL−
BELL+
AC
AC
EARTH
POS
NEG
LAN+
OUTPUT 1
−
ZONE 2
COM
−
+
J11
Summary of Contents for xGenConnect
Page 1: ...xGenConnect Installation and Programming Guide P N 466 5545 EN REV J ISS 26OCT22...
Page 4: ......
Page 12: ...viii xGenConnect Installation and Programming Guide...
Page 93: ...xGenConnect Installation and Programming Guide 81 Web Page...
Page 109: ...xGenConnect Installation and Programming Guide 97 Instructions 1 Go to Zone Type...
Page 117: ...xGenConnect Installation and Programming Guide 105 Webpage...
Page 156: ...144 xGenConnect Installation and Programming Guide...
Page 166: ...154 xGenConnect Installation and Programming Guide...