xGenConnect Installation and Programming Guide
NXG-9
13.8
VDC ± 0.2 V, 570 mA max.
Battery type
Certified sealed lead acid rechargeable.
7.2 Ah 12 V nominal
12 Ah 12 V nominal (NXG-8 and NXG-9 only)
18 Ah 12 V nominal (NXG-8 only)
Minimum energy level of the battery in its charged
state is 100%
Minimum voltage
9.45 VDC
Maximum voltage at power supply, auxiliary
power output and battery power output
14.5 VDC
Battery low condition
11.3 to 11.8 VDC
Battery disconnect voltage
9.77 VDC
Maximum ripple voltage V, p-p
200 mV typical, 550 mV max.
General Features
Code combinations:
xGenConnect
From 10,000 (4 digits) to 100,000,000 (8 digits)
Maximum user number:
NXG-4
40
NXG-8, NXG-9
100
NXG-8E
256
User Permissions:
NXG-4
32
NXG-8, NXG-9
64
NXG-8E
128
Onboard zones:
NXG-4
4 (default); 8 if zone doubling enabled.
NXG-8(E), NXG-9
8 (default); 16 if zone doubling enabled.
Maximum zone number:
NXG-4
16
NXG-8, NXG-9
48
NXG-8E
192
Additional inputs:
NXG-4, NXG-8(E)
1: box tamper
NXG-9
2: box tampers
End-of-line resistor
Standard
4.7
kΩ / 9.4 kΩ (Aritech), 4.1 kΩ / 8.2 kΩ (Guardall),
1 kΩ / 2 kΩ (Galaxy), 3.3 kΩ / 6.6 kΩ (NX)
Aritech
4.7 kΩ / 9.4 kΩ / 14.7 kΩ / 19.4 kΩ
Guardall
4.1
kΩ / 8.2 kΩ / 12.3 kΩ / 16.4 kΩ
Galaxy
1
kΩ / 2 kΩ
Vanderbilt
4.7
kΩ / 9.4 kΩ / 6.9 kΩ / 11.6 kΩ
2-wire smoke
820
Ω
Summary of Contents for xGenConnect
Page 1: ...xGenConnect Installation and Programming Guide P N 466 5545 EN REV J ISS 26OCT22...
Page 4: ......
Page 12: ...viii xGenConnect Installation and Programming Guide...
Page 93: ...xGenConnect Installation and Programming Guide 81 Web Page...
Page 109: ...xGenConnect Installation and Programming Guide 97 Instructions 1 Go to Zone Type...
Page 117: ...xGenConnect Installation and Programming Guide 105 Webpage...
Page 156: ...144 xGenConnect Installation and Programming Guide...
Page 166: ...154 xGenConnect Installation and Programming Guide...