xGenConnect Installation and Programming Guide
63
description of all door-related parameters is available in
xGenConnect Reference
Guide
.
Setting Menu > Door Settings
• Door Name: Program up to a 32-character custom name for the selected
door. This name appears in every list in the system, including keypad
controlling doors.
• Door Type: Select this submenu to enable the door with the desired
combination of Door Input Zone Shunting (Shunt), Forced Door Monitoring
(Forced), Door Left Open (DLO) monitoring.
• Door Inputs: Choose desired system zone inputs for the door zone, and the
Request-to-Exit (RTE) zone. The door zone input can be part of the alarm
system and can have any appropriate zone type. The RTE zone should not
be used by the alarm system except for exit requesting buttons.
Note:
Door zone should not be configured if Door type is Lock or Disabled. All
other door types require Door zone to be properly set.
Both Door zone and Request-to-Exit can be wired to the NXG-1832 / NXG-
1833-EUR keypad Input, using a special triple-EOL resistor configuration (see
the keypad Installation Sheet for details).
In this case, the following parameters must be set properly:
- panel Door Zone parameter must be set to a particular desired zone number
(for example, 1).
Summary of Contents for xGenConnect
Page 1: ...xGenConnect Installation and Programming Guide P N 466 5545 EN REV J ISS 26OCT22...
Page 4: ......
Page 12: ...viii xGenConnect Installation and Programming Guide...
Page 93: ...xGenConnect Installation and Programming Guide 81 Web Page...
Page 109: ...xGenConnect Installation and Programming Guide 97 Instructions 1 Go to Zone Type...
Page 117: ...xGenConnect Installation and Programming Guide 105 Webpage...
Page 156: ...144 xGenConnect Installation and Programming Guide...
Page 166: ...154 xGenConnect Installation and Programming Guide...