Arm/Disarm Your System with Simplified Arm-Disarm
mode enabled
The NXG-183x-EUR keypad can be configured to arm and disarm the system in
a simplified way. If the Simplified arm-disarm mode is enabled, pressing any of
the numeric keys automatically starts entering user PIN.
Note:
This mode is available for 4- or 6-digit PINs only.
You can enter your PIN (4 or 6 digits, depending on the system settings) without
pressing the Enter key, or arm-disarm buttons.
If the appropriate partitions are armed or in alarm, entering a valid PIN code will
disarm the system. If the partitions are disarmed, entering a valid PIN code will
arm these in the Away mode.
Notes
• It is recommended (but not required) to disable the Idle PIN and Display
partition list options to take all advantages of Simplified arm-disarm mode.
• If the Display partition list option is enabled, it is not required in the Simplified
arm-disarm mode to press Enter after selecting the partitions to operate. If
any partition is selected, the selection is automatically confirmed 5 seconds
after the last key is pressed.
• The screensaver is not deactivated automatically. If the screensaver is active,
press any button first to deactivate the screensaver, and then start entering
your PIN.
• The operation to perform in Simplified arm-disarm mode is chosen based on
the state of all partitions that the user has the permission to disarm (relevant
only if custom users are configured).
• If the Simplified arm-disarm mode is enabled and any partition is armed, you
cannot access the keypad menu by pressing the Enter key.
Example:
User PIN is 1234, Simplified arm-disarm mode is set to 4-digit mode, Idle PIN is
disabled.
To arm or disarm the partitions, follow these steps:
1. If the screensaver is active, press any button to deactivate it.
2. Press 1, 2, 3, 4.
System arms or disarms, depending on its current state.
Arm/Disarm Your System with NXG-1832 / NXG-1833-
EUR keypad and user card
The system can be armed/disarmed by presenting a card or tag to the NXG-1832
/ NXG-1833-EUR keypads, which are equipped with a built-in Mifare card reader.
The following configuration steps must be taken to allow arming and disarming
via a user card or tag:
Summary of Contents for xGenConnect
Page 1: ...xGenConnect Installation and Programming Guide P N 466 5545 EN REV J ISS 26OCT22...
Page 4: ......
Page 12: ...viii xGenConnect Installation and Programming Guide...
Page 93: ...xGenConnect Installation and Programming Guide 81 Web Page...
Page 109: ...xGenConnect Installation and Programming Guide 97 Instructions 1 Go to Zone Type...
Page 117: ...xGenConnect Installation and Programming Guide 105 Webpage...
Page 156: ...144 xGenConnect Installation and Programming Guide...
Page 166: ...154 xGenConnect Installation and Programming Guide...