xGenConnect Installation and Programming Guide
13
• Overriding is not supported with xGenConnect. In case a zone is faulted, one
shall bypass the zone manually before arming or verify the zone and clear the
fault. See user instructions.
• Hold-up zones are not allowed to be set for bypass.
• Zone isolation is not supported.
• EN 50136-2 (Alarm transmission systems and equipment – Part 2:
Requirements for Supervised Premises Transceiver (SPT):
- Upon configuring alarm transmission path and remote connection details,
default user/installer keys shall be changed.
Options Affected by EN 50131 Regulations
EN 50131 Grade 2 Required settings
The following options and values are mandatory for EN 50131-1 Grade 2
regulations.
• Period, 24 h for every path to meet ATS Class 2, 4 h for the IP path to meet
Class 4.
• View Partitions and Control Partitions settings are identical
• Buzzer silent, never
• Quick set, off
• Function keys, all set to None
• User group options, No OP/CL reports option set to No
• Inhibit, set to No for all zones with type Panic, 24H
• Swinger shunt, set to Yes for all zones
• ACK on keypad, set to None for all zones with type Keyswitch
• Entry time, 45 s maximum
• Entry alarms, Instant
• Active, set to No for all schedules.
• Activation, internal and external siren 90 to 900 s
• Delay time, external siren 600 s maximum
• Armed display, 30 s maximum
• Mains reporting delay 10 to 70 s
• User code required, enabled
• Armed display, always
• Alarm list, disabled
• Inhibit includes, all allowed except engineer reset, which must be disabled
• Pending alarms, enabled
• Swinger shunt ≥ 3
• Report restore, on ACK
• Line fault, enabled per path used
• Line fault delay, 0 s
• Partition option to override EN50131-1 Arming Cancelation set to No
• User option not to report open/close events – only with at least one CIE
(Control and Indicating Equipment) in the system
Refer to
xGen Reference Guide
for additional features, accessible at level 3.
Summary of Contents for xGenConnect
Page 1: ...xGenConnect Installation and Programming Guide P N 466 5545 EN REV J ISS 26OCT22...
Page 4: ......
Page 12: ...viii xGenConnect Installation and Programming Guide...
Page 93: ...xGenConnect Installation and Programming Guide 81 Web Page...
Page 109: ...xGenConnect Installation and Programming Guide 97 Instructions 1 Go to Zone Type...
Page 117: ...xGenConnect Installation and Programming Guide 105 Webpage...
Page 156: ...144 xGenConnect Installation and Programming Guide...
Page 166: ...154 xGenConnect Installation and Programming Guide...