Chapter 17 Displaying Status Information
17-26
CSMIM/Micro-CS Management Application Guide
❑
Red History
indicates whether a Red alarm has occurred since
the T1 Engine has been online. This field displays
True
or
False
.
❑
Red
reports the current status of the Red alarm. If this field
displays
On
, the T1 engine is detecting loss of frame
synchronization and is sending a Yellow alarm to the network.
❑
Yellow History
indicates whether a Yellow alarm has occurred
since the T1 Engine has been online. This field displays
True
or
False
.
❑
Yellow
indicates the current status of the Yellow alarm. If this
field displays
On
, the T1 engine is receiving a yellow alarm from
the network.
Understanding the T1 Status Box
The
T1 Status
box displays statistics for the T1 network interface. This box
includes the following categories:
❑
Engine Bypass
indicates whether the engine is connected to the
Network Interface This field displays
enabled
or
disabled.
If it
displays
disabled
, the engine is connected to the Network
Interface.
❑
Sync
indicates whether the T1 engine is detecting frame
synchronization. If this field displays
False
, the T1 engine has
lost frame synchronization and has entered the red alarm state.
❑
DII Sync
indicates whether the Drop and Insert Interface is
receiving ones pulses and is in frame sync. This field displays
True
or
False
to indicate the interface status.
❑
Signal Loss
indicates whether the T1 engine is detecting pulses
on the T1 network interface receivers. If the engine is not
detecting pulses, the T1 engine transmits AIS (all ones,
unframed) on the T1 network interface. This field displays
True
when the engine is not detecting pulses and
False
when it is
detecting pulses.
❑
Loopback Mode
indicates loopback status. This field can display:
❑
Noloop
to show that the signal is not looped through the T1
engine.
Summary of Contents for CSMIM-T1
Page 1: ...Title Page CSMIM MICRO CSMANAGEMENTAPPLICATION ADMINISTRATOR S GUIDE ...
Page 2: ......
Page 22: ...Preface 10 CSMIM Micro CS Management Application Guide ...
Page 32: ...Chapter 1 Installing Annex Manager 1 10 CSMIM Micro CS Management Application Guide ...
Page 54: ...Chapter 2 Window Basics 2 22 CSMIM Micro CS Management Application Guide ...
Page 74: ...Chapter 3 Working with Annex Manager Windows 3 20 CSMIM Micro CS Management Application Guide ...
Page 94: ...Chapter 4 Using the Main Window 4 20 CSMIM Micro CS Management Application Guide ...
Page 152: ...CSMIM Micro CS Management Application Guide 10 4 Figure 10 2 Reset Parameters Window ...
Page 240: ...Chapter 16 Booting and Resetting Annexes 16 20 CSMIM Micro CS Management Application Guide ...
Page 286: ...Chapter 17 Displaying Status Information 17 46 CSMIM Micro CS Management Application Guide ...
Page 300: ...Chapter 18 Annex Manager and SNMP 18 14 CSMIM Micro CS Management Application Guide ...