Using the Call Defaults Window
CSMIM/Micro-CS Management Application Guide
8-7
❑
CLI Inactivity Timer
specifies the amount of time in minutes
that the ISDN Primary Rate Annex remains idle before
disconnecting a CLI session. Entering
0
(zero) disables the
timer; entering
255
causes the Annex to disconnect as soon
as it exits from its last job. You can enter any number of
minutes up to 255. Unlike the call inactivity timer, this timer
does not disconnect a CLI session with active jobs.
❑
Call Inactivity Timer
specifies the number of minutes that a
connection can remain inactive. If the timer expires, the
Annex terminates the call. You can use the
Input is Activity
and
Output Is Activity
buttons to define incoming call activity.
If you do not use these buttons, the timer runs independent
of activity. You can enter any number of minutes up to 255
minutes.
❑
Input Is Activity
buttons define activity as input. If you click the
On
button, the Annex resets the inactivity timer when it receives
input through an established call.
❑
Output Is Activity
buttons defines activity as output. If you click the
On
button, the Annex resets the inactivity timer when it sends
output.
The
PPP Security
box defines data for authorization on a remote PPP peer.
This box uses the following fields:
❑
Remote Username
contains the user name by which the ISDN
Primary Rate Annex identifies itself when the remote PPP peer
asks for authentication. This name can contain up to 15
characters.
❑
Remote Password
defines the password that the ISDN Primary
Rate Annex uses when the remote PPP peer requests
authentication. For security reasons, Annex Manager displays
this parameter's value as
set
or
unset
. This name can contain up
to 15 characters.
The
Modem
box provides access to the
Edit Modem
window.
When an option is unavailable it appears in grey: you
cannot select such options.
Summary of Contents for CSMIM-T1
Page 1: ...Title Page CSMIM MICRO CSMANAGEMENTAPPLICATION ADMINISTRATOR S GUIDE ...
Page 2: ......
Page 22: ...Preface 10 CSMIM Micro CS Management Application Guide ...
Page 32: ...Chapter 1 Installing Annex Manager 1 10 CSMIM Micro CS Management Application Guide ...
Page 54: ...Chapter 2 Window Basics 2 22 CSMIM Micro CS Management Application Guide ...
Page 74: ...Chapter 3 Working with Annex Manager Windows 3 20 CSMIM Micro CS Management Application Guide ...
Page 94: ...Chapter 4 Using the Main Window 4 20 CSMIM Micro CS Management Application Guide ...
Page 152: ...CSMIM Micro CS Management Application Guide 10 4 Figure 10 2 Reset Parameters Window ...
Page 240: ...Chapter 16 Booting and Resetting Annexes 16 20 CSMIM Micro CS Management Application Guide ...
Page 286: ...Chapter 17 Displaying Status Information 17 46 CSMIM Micro CS Management Application Guide ...
Page 300: ...Chapter 18 Annex Manager and SNMP 18 14 CSMIM Micro CS Management Application Guide ...