Commissioning via Busch-free@home®
Product manual 2CKA001473B5342
│
56
Under the channel settings you can configure the settings described in the following.
Pos.
Description
[1]
Device name
An independent designation for the device can be allocated via the text field.
[2]
Position
By tapping on the drop-down menu you can assign a position to the device in the
building structure you defined (e.g. assignment to a room on a certain floor).
[3]
Room temperature sensor
The internal room temperature controller can be set by tapping on the button. You can
switch it on and off, set the actual temperature and specify the operating mode.
[4]
Time programs
This overview displays all previously created time programs. The number after a time
program indicates how often the actuator is used in this time profile. Select a time
program for adding it to the actuator.
[5]
Authorizations
Menu item "Authorizations" is used to specify whether a user with installer authorization
is required for the reconfiguration of the actuator.
In addition, you can nevertheless assign users with read rights the authorization to
switch this actuator.
[6]
Parameters
Eco temperature reduction
[°C]
The
−
/+ buttons can be used to specify by how
many degrees the temperature is to be reduced to
when ECO mode is activated.
Temperature correction [°C]
Manual increase/reduction of the temperature value
via the -/+ buttons to adjust a permanent
temperature offset.
Switch-off delay during
absence [s]
If the ECO mode is deactivated by a movement
detector, the switch-off delay can be specified here
when the ECO mode is to be re-activated after the
room is exited.
Use of internal/external
temperature reading
The following selection options are available for the
temperature reading.
■
Internal for regulating:
– Use of the internal temperature sensor of the
device for reading and regulating the room
temperature.
■
External for regulating:
– Use of an external temperature sensor for
reading and regulating the floor temperature.
For this the external temperature sensor must
be laid in the screed.
■
Internal and external for regulating:
– Use of the internal and an external
temperature sensor for reading and regulating
the room temperature. Both measured values
are used to create an average value. For this
the external temperature sensor must be
installed behind a ventilated cover plate (e.g.
6541-xx).
■
Internal for regulating and external for
limiting:
– Use of the internal and an external
temperature sensor for reading temperature.
The temperature is regulated via the internal
temperature sensor. The external temperature
sensor serves for limiting the temperature,