Using your LinkStation
LinkStation User Manual
105
UPS Settings
A UPS (uninterruptable power supply) can automatically shut down your LinkStation in case of a
power outage. To use the LinkStation with a UPS, configure the following settings.
Note:
Not all LinkStations support UPSs. Check the LinkStation Function List on page 35 to see if your
LinkStation supports UPSs.
1
2
3
Plug the Power cable of UPS to a wall socket.
Connect the AC adapter of the LinkStation to the UPS.
Connect the UPS and the LinkStation with a USB cable.
4
Turn on the UPS, then the LinkStation.
5
In the Web Admin interface, navigate to [System] -
[Power Management] - [UPS Settings] and click [Modify
Settings].
6
The LinkStation is now configured to work with the UPS.
Note:
If the LinkStation shuts down automatically due to a power outage, make sure that the power issue
is resolved before turning it back on. If the LinkStation is turned back on while it’s still running on
the UPS battery, the UPS will not shut it down again, even if the battery runs low.
System - Power Management
1
If your LinkStation is connected directly to the
UPS, select [synchronize with UPS connected
to this LinkStation]. To have the UPS shut down
multiple LinkStations on the same network, select
[synchronize with UPS connected to other LinkStation
on the network] and enter the IP address of the
LinkStation that is connected directly to the UPS in
the field below.
2
Click [Save].