LinkStation User Manual
196
Appendix
Info/Error LED
The Info/Error LED blinks orange when it has a message. The message is coded by the pattern of
blinking.
Note:
The messages are also available (uncoded) in NAS Navigator2.
Information code
Descriptions
I10
System temperature may have exceeded the maximum safe value. Move
the LinkStation to a cooler location. Do not place objects in the area around
the LinkStation.
I11
The bad sectors in the hard drive may have reached a dangerous level.
Replace the hard drive.
I12
Operating in degraded mode.
I13
Formatting the RAID array.
I14
Checking the RAID array.
I15
Examining the error status of the RAID array. Transfer speeds are slower
during the examination process.
I16
Creating the RAID array.
I17
Resyncing the RAID array. Transfer speeds are slower during the resyncing
process.
I18
Rebuilding the RAID array. Transfer speeds are slower during the rebuilding
process.
I19
Writing 0s to the RAID array, erasing all data.
I20
Checking the hard drive.
I21
Checking the hard drive.
I22
Erasing the data for the hard drive.
I25
Updating the LinkStation firmware. Do not turn off the power during the
updating process.
Place
Status
10s place
The LED illuminates for 1.0 second every 0.3 seconds.
The number of flashes is the tens place of the information code.
1s place
The LED illuminates for 0.5 seconds every 0.3 seconds.
The number of flashes is the ones place of the information code.