VIBROTEST 60
Technical Data
_________________________________________________________________________________
© VTEST60E July 2013 V4.46ff
C102 853.002
Page 153 of 168
BCU
Accuracy:
4 % of measured value
Process-values
(only possible through channel 1)
Frequency band:
0 Hz ... 20 kHz
Voltage input range:
-30 V ... +30 V
Input resistance:
150 k
Ω
Current input range:
0/4 ... 20 mA
Input resistance. R
E
100
Ω
Accuracy:
Voltage:
± 0,3 V
Current:
± 0,5 mA
Spectra
Freq. range:
1 Hz ... 20 Hz,
1 Hz ... 20 kHz
No. of Lines:
100, 200, 400, ... 6400, 12800
Window types:
Flat-top, Hanning, Uniform
Speed
Signal voltage:
0,5 ... 30 Vpp
Input frequency range:
0,5 Hz ... 10 kHz
Input resistance
22 k
Ω
Translation ratio:
Impulse / Revoution
1 ... 99 / 1 ... 99
With a translation ratio of 1 : 1 this gives a Speed range:
30 ... 600,000 RPM
Accuracy:
1
*
10
-3
of measured value
(0,01 Hz or 1 RPM)
Tracking Analysis (Balancing)
Amplitude
Reproducibility ± 4 %
Phase
Accuracy ± 1 degree
Freq. range (tracking)
1,0 Hz … 10 kHz
Freq. range (balancing)
0,8 Hz ... 10 kHz
Reference frequency
max. 20kHz