Field Balancing
VIBROTEST 60
Page 128 of 168
C102 853.002
© VTEST60E July 2013 4.46ff
VIBROTEST 60 dialogue
VIBROTEST 60 steps
Activity at Rotor
Stop the measurement with
»STOP«.
4.
Execute Check
measurement
The VIBROTEST 60 executes the
measurement at both planes.
With function button »1/2« the
measurement from plane 2 is
displayed.
The measurement at both planes is
stopped with »STOP«.
Store the measurements
with »OK«.
5.
Store Check meas-
urement
With »OK« the measurements from
both planes are stored and the
additional correction weights are
calculated.
Stop the rotor.
6.
Calculate residual
unbalance
The VIBROTEST 60 calculates the
additional correction weights for both
planes.
In the main menu the following are
displayed for plane A:
•
Calculated correction weights
(CMA) and their locations.
•
Measurements from the Check
run (CR).
•
Speed of the Check run
With the function button »1/2« the
respective results for plane B are
displayed.
»SELECT«,»CR=IR«, »ADD«,
see 1-plane Balancing;
Section 7.5, Check run, point 7
Assess whether the
recommended
additional correction is
necessary.