VIBROTEST 60
Field Balancing
_________________________________________________________________________________
© VTEST60E July 2013 V4.46ff
C102 853.002
Page 121 of 168
VIBROTEST 60 dialogue
VIBROTEST 60 steps
Activity at Rotor
Store the measurement with
»OK«.
5.
Store the Check
measurement
The measurement is stored with
»OK« and the correction weight is
calculated.
Stop the rotor.
6.
Store the measure-
ment with »OK
The VIBROTEST 60 calculates the
correction weight.
The following are displayed in the
main menu:
•
Calculated correction weight
(CMA).
•
Result of the Check run (CR).
•
Speed of the Check run
»SELECT«
The Check run can be repeated with
»SELECT«. In the case of a repeat
the VIBROTEST 60 assumes that the
correction has been carried out at the
rotor.
»CR=IR«
The Check run can be accepted as
the Initial run in a new balancing
procedure with »CR=IR«.
Function button »STORE«
With the function button »STORE« a
new balancing proce-dure is stiored
on the PC-card.
Carry out the correction
at the rotor.
The correction should
not be carried out at
the rotor.