Acquiring and displaying measurements
VIBROTEST 60
Page 64 of 168
C102 853.002
© VTEST60E July 2013 4.46ff
5.1
»Overall Vibration / BCU measurement«
Measured value 1:
Vibration
Measured value 2:
Bearing Condition
Measured value 3: Speed
Unit
Signal detection
Unit
Unit
START The measurement is started. „STOP„ is displayed
and the channel number flashes to indicate that the
measurement is in progress.
STOP
The measurement is ended. „START„ is displayed to
indicate that the measurement has stopped.
REC
Activate the measurement recording vs. speed or
time. The measurement process is ended manually
with „STOP“ or automatically when f
max
/f
min
is reached
(run-up / coast-down).
AVERAGE On / Off switch for the averaging function.
The measurement process for »Overall / BCU«, or »Process-
value« remains active until the »STOP« button is pushed.
The display or updating of the measurement is done after each
acquisition step. The last measured value is retained until a
new measurement is started or selection of a new measure-
ment order is made.
The units displayed conform to the configuration »Overall
Setup« and »System Setup«.
Note:
If measured values and their units (e.g. BCU or RPM) are not
displayed, these measurement types have not been activated.
These measurement types can be activated using the »Overall
Setup« and »System Setup« functions.