VIBROTEST 60
Field Balancing
_________________________________________________________________________________
© VTEST60E July 2013 V4.46ff
C102 853.002
Page 127 of 168
VIBROTEST 60 dialogue
VIBROTEST 60 steps
Activity at Rotor
Check Run
A
B
1
2
Select the Check run with
»SELECT«.
1.
Select Check run in
the main menu
2.
Change the correction
weights
The correction weights for both
planes can be changed.
•
»+/-«: Convert the dis-played
correction weights from „Add
weight„ to „Remove weight„ or
vice versa.
•
»EDIT«: Change the magni-tudes
and locations of the correction
weights.
It is recommended that you attach the
calculated correction weights to the
rotor. Other correction weights should
only be used when the calculated
correction weights are not available.
The VIBROTEST 60 should then be
informed of the correction weight
changes with »EDIT«.
Start the measurement with
»START«.
3.
Start the Check run
The measurement is executed by the
VIBROTEST 60 with »START«.
The correction weights (CMA) for
plane A are displayed in the
measurement menu.
Bring the rotor to
operational speed.