478
Fabric OS Administrator’s Guide
53-1001763-02
LSAN zone configuration
21
LSAN zones and fabric-to-fabric communications
Zoning is enforced by all involved fabrics; any communication from one fabric to another must be
allowed by the zoning setup on both fabrics. If the SANs are under separate administrative control,
then separate administrators maintain access control.
Controlling device communication with the LSAN
The following procedure illustrates how LSANs control which devices can communicate with each
other. The procedure shows the creation of two LSANs (called
lsan_zone_fabric75
and
lsan_zone_fabric2
), which involve the following devices and connections:
•
Switch1 and the host in fabric75.
•
Switch2, Target A, and Target B in fabric2.
•
Switch1 is connected to the FC router using an EX_Port or VEX_Port.
•
Switch2 is connected to the FC router using another EX_Port or VEX_Port.
•
Host has WWN 10:00:00:00:c9:2b:c9:0c (connected to switch1).
•
Target A has WWN 50:05:07:61:00:5b:62:ed (connected to switch2).
•
Target B has WWN 50:05:07:61:00:49:20:b4 (connected to switch2).
1. Log in as admin and connect to switch1.
2. Enter the nsShow command to list the WWN of the host (10:00:00:00:c9:2b:c9:0c).
NOTE
The nsShow output displays both the port WWN and node WWN; the port WWN must be used
for LSANs.
switch:admin>
nsshow
{
Type Pid
COS PortName
NodeName
TTL(sec)
N 060f00;
2,3;
10:00:00:00:c9:2b:c9:0c;
20:00:00:00:c9:2b:c9:0c; na
FC4s: FCP
NodeSymb: [35] "Emulex LP9002 FV3.91A3 DV5-5.20A6 "
Fabric Port Name: 20:0f:00:05:1e:37:00:44
Permanent Port Name: 10:00:00:00:c9:2b:c9:0c
The Local Name Server has 1 entry }
3. Enter the zoneCreate command to create the LSAN
lsan_zone_fabric75
, which includes the
host.
switch:admin>
zonecreate "lsan_zone_fabric75", "10:00:00:00:c9:2b:c9:0c"
4. Enter the zoneAdd command to add Target A to the LSAN.
FID75Domain5:admin>
zoneadd "lsan_zone_fabric75", "50:05:07:61:00:5b:62:ed"
5. Enter the cfgAdd or cfgCreate and cfgEnable commands to add and enable the LSAN
configuration.
switch:admin>
cfgadd "zone_cfg", "lsan_zone_fabric75"
switch:admin>
cfgenable "zone_cfg"
You are about to enable a new zoning configuration.
This action will replace the old zoning configuration with the
current configuration selected.
Summary of Contents for 53-1001763-02
Page 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Page 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Page 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Page 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Page 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Page 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Page 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Page 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Page 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Page 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Page 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...