Fabric OS Administrator’s Guide
261
53-1001763-02
Zoning configuration management
11
4. Enter the cfgShow command to verify the renamed zone object is present.
5. If you want the change preserved when the switch reboots, enter the cfgSave command to
save it to nonvolatile (flash) memory.
6. Enter the cfgEnable command for the appropriate zone configuration to make the change
effective.
Zoning configuration management
You can add, delete, or remove individual elements in an existing zone configuration to create an
appropriate configuration for your SAN environment. After the changes have been made, save the
configuration to ensure the configuration is permanently saved in the switch and that the
configuration is replicated throughout the fabric.
The switch configuration file can also be uploaded to the host for archiving and it can be
downloaded from the host to a switch in the fabric. See
“Configuration file backup”
on page 178,
“Configuration file restoration”
on page 180, or the configUpload and configDownload commands
in the
Fabric OS Command Reference
for additional information on uploading and downloading the
configuration file.
New switch or fabric additions
When a new switch is added to the fabric, it automatically takes on the zone configuration
information from the fabric. You can verify the zoning configuration on the switch using the
procedure described in
“Viewing the configuration in the effective zone database”
on page 258.
If you are adding a switch that is already configured for zoning, clear the zone configuration on that
switch before connecting it to the zoned fabric. See
“Clearing all zone configurations”
on page 258
for instructions.
Adding a new fabric that has no zone configuration information to an existing fabric is very similar
to adding a new switch. All switches in the new fabric inherit the zoning configuration data. If a zone
configuration is in effect, then the same configuration becomes the enabled configuration.
Before the new fabric can merge successfully, it must pass the following criteria:
•
Before merging zones
To facilitate merging, check the following before merging switches or fabrics:
-
Zoning licenses: All switches running Fabric OS v6.0.x or earlier must have a Zoning
license enabled.
-
Native operating mode: All switches must be in the native operating mode.
-
Default Zone: The switch being merged into the existing fabric should be configured with
the same default zone mode as the existing switches.
•
Merging and segmentation
The fabric is checked for segmentation during power-up or when a switch is disabled or
enabled, or when a new switch is added.
Summary of Contents for 53-1001763-02
Page 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Page 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Page 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Page 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Page 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Page 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Page 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Page 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Page 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Page 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Page 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Page 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...