10
Fabric OS Administrator’s Guide
53-1001763-02
Device login
1
*MS Topology Discovery disabled locally.
switch:admin>
mstddisable all
This may erase all NID entries. Are you sure? (yes, y, no, n): [no]
y
Request to disable MS Topology Discovery Service in progress....
*MS Topology Discovery disabled locally.
*MS Topology Discovery Disable Operation Complete!!
Device login
A device can be a storage, host, or switch. When new devices are introduced into the fabric, they
must be powered on and, if a host or storage device, connected to a switch. The switch must be
connected to another switch. E_Ports exchange different frames than the ones listed below with
the Fabric Controller to access the fabric. Once storage and host devices are powered on and
connected, the following logins occur:
1. FLOGI—Fabric Login command establishes a 24-bit address for the device logging in, and
establishes buffer-to-buffer credits and the class of service supported.
2. PLOGI—Port Login command logs the device into the Name Server to register its information as
well as query for devices that share its zone. During the PLOGI process, information is
exchanged between the new device and the fabric. A few of the following types of information
exchanges occur:
•
SCR—State Change Registration registers the device for State Change Notifications. If
there is a change in the fabric, such as a zoning change or a change in the state of a
device to which this device has access, the device will receive a Registered State Change
Notification (RSCN).
•
Registration—A device exchanges registration information with the Name Server.
•
Query—Devices query the Name Server for information about the device it can access.
Principal switch
In a fabric with multiple switches, and one inter-switch link (ISL) exists between any two switches, a
principal switch is automatically elected. The principal switch provides the following capabilities:
•
Maintains time for the entire fabric. Subordinate switches synchronize their time with the
principal switch. Changes to the clock server value on the principal switch are propagated to all
switches in the fabric.
•
Manages domain ID assignment within the fabric. If a switch requests a domain ID that has
been used before, the principal switch grants the same domain ID unless it is in use by another
switch.
E_Port login
An E_Port does not use a FLOGI to log in to another switch. Instead, the new switch exchanges
frames with the principal switch to establish that the new switch is an E_Port and that it has
information to exchange. If everything is acceptable to the principal switch, it replies to the new
switch with an SW_ACC (accept) frame. The initializing frame is an Exchange Link Parameters (ELP)
frame that allows an exchange of parameters between two ports, such as flow control,
buffer-to-buffer credits, RA_TOV, and ED_TOV. This is not a negotiation. If one or the other port’s link
Summary of Contents for 53-1001763-02
Page 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Page 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Page 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Page 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Page 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Page 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Page 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Page 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Page 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Page 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Page 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Page 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...