Blade terminology and compatibility
3
CP blades
The control processor (CP) blade provides redundancy and acts as the brains of the
enterprise-class platform. The Brocade 48000 supports the CP256 blade. The Brocade DCX and
DCX-4S support the CP8 blades.
The CP blades in the Brocade DCX and DCX-4S are hot-swappable. When the CPs from a Brocade
DCX are inserted into a Brocade DCX-4S, the switch type changes. The same is true when inserting
a CP blade from a Brocade DCX-4S into a Brocade DCX. When a CP blade with a Fabric OS prior to
v6.2.0 is inserted into a Brocade DCX-4S, the blade becomes faulty. You can correct this issue by
upgrading the firmware on the CP blade in a Brocade DCX or DCX-4S chassis.
Mixed CP blades are not supported on a single chassis, except during specific upgrade procedures
detailed in the
Brocade 48000 Hardware Reference Manual
. CP4 and CP8 blades cannot be
mixed in the same chassis under any circumstances. Brocade recommends that each Brocade
platform have only one type of CP blade installed and that each CP (primary and secondary
partition) maintains the same firmware version.
For more information on maintaining firmware in your enterprise-class platform, refer to
Chapter 9,
“Installing and Maintaining Firmware”
.
Core blades
Core blades provide intra-chassis switching and ICL connectivity between DCX platforms. The
Brocade DCX supports two CORE8 core blades. The Brocade DCX-4S supports two CR4S-8 core
blades. This blade is not interchangeable or hot-swappable with the Brocade DCX core blades. If
you try to interchange the blades they become faulty.
The Brocade 48000 does not support core blades.
Port and application blade compatibility
Table 5
identifies which port and application blades are supported for each Brocade platform.
TABLE 5
Port blades supported by each platform
Port blades
Brocade 48000 (CP4)
Brocade DCX and DCX-4S
FA4-18
Supported
Supported
FC10-6
Supported
Supported
FC4-16
Supported
Unsupported
FC4-16IP
Supported
Unsupported
FC4-32
Supported
Unsupported
FC4-48
Supported
Unsupported
FC8-16
Supported
Supported
FC8-32
Supported
Supported
FC8-48
Supported
Supported
FC8-64
Unsupported
Supported
FCOE10-24
1
Unsupported
Supported
FR4-18i
Supported
Supported
Summary of Contents for 53-1001763-02
Page 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Page 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Page 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Page 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Page 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Page 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Page 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Page 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Page 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Page 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Page 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Page 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...