Fabric OS Administrator’s Guide
139
53-1001763-02
FCS policies
7
NOTE
FCS policy must be consistent across the fabric. If the policy is inconsistent in the fabric, then you
will not be able to perform any fabric-wide configurations from the primary FCS.
Modifying the order of FCS switches
1. Log in to the Primary FCS switch using an account assigned to the admin role.
2. Type secPolicyShow “Defined”, “FCS_POLICY”.
This displays the WWNs of the current Primary FCS switch and backup FCS switches.
3. Type secPolicyFCSMove; then provide the current position of the switch in the list and the
desired position at the prompts.
Alternatively, enter secPolicyFCSMove [
From, To
] command.
From
is the current position in the
list of the FCS switch and
To
is the desired position in the list for this switch.
Example of moving an FCS policy
The following example moves a backup FCS switch from position 2 to position 3 in the FCS list,
using interactive mode:
primaryfcs:admin>
secpolicyfcsmove
PosPrimary WWN
DId
swName.
=================================================
1Yes
10:00:00:60:69:10:02:181
switch5.
2No
10:00:00:60:69:00:00:5a2
switch60.
3No
10:00:00:60:69:00:00:133
switch73.
Please enter position you’d like to move from : (1..3) [1]
2
Please enter position you’d like to move to : (1..3) [1]
3
____________________________________________________
DEFINED POLICY SET
FCS_POLICY
PosPrimaryWWN
DId swName
__________________________________________________
1Yes
10:00:00:60:69:10:02:181 switch5.
2No
10:00:00:60:69:00:00:133 switch73.
3No
10:00:00:60:69:00:00:5a2 switch60.
____________________________________________________
4. Type the secPolicyActivate command to activate and save the new order.
FCS policy distribution
The FCS policy can be automatically distributed using the fddCfg
--
fabwideset command or it can
be manually distributed to the switches using the distribute -p command. Each switch that receives
the FCS policy must be configured to receive the policy. To configure the switch to accept
distribution of the FCS policy, refer to
“Database distribution settings”
on page 159.
Database distributions may be initiated from only the Primary FCS switch. FCS policy configuration
and management is performed using the command line or a manageability interface.
Summary of Contents for 53-1001763-02
Page 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Page 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Page 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Page 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Page 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Page 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Page 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Page 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Page 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Page 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Page 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Page 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...