Fabric OS Administrator’s Guide
185
53-1001763-02
Configuration management for Virtual Fabrics
8
Uploading a configuration file from a switch with Virtual Fabrics
enabled
The configUpload command with the -vf option specifies that configuration upload will upload the
Virtual Fabric configuration instead of the non-Virtual Fabric configuration information.
You must specify a filename with the configUpload -vf command. It is recommended not to use
config.txt for a filename as this can easily be confused with a normal uploaded configuration file.
Example of configUpload on a switch with Virtual Fabrics
Sprint5100:FID128:admin>
configupload
Protocol (scp, ftp, local) [ftp]:
Server Name or IP Address [host]:
10.1.2.3
User Name [user]:
UserFoo
Path/Filename [<home dir>/config.txt]:
5100.txt
Potentially remote file may get overwritten
Section (all|chassis|FID# [all]):
Password:
<hidden>
configUpload complete: All selected config parameters are uploaded
Example of configUpload of a logical switch configuration
DCX_80:FID128:admin>
configupload -vf
Protocol (scp, ftp, local) [ftp]:
Server Name or IP Address [host]:
10.1.2.3
User Name [user]:
anonymous
Path/Filename [<home dir>/config.txt]:
configUpload complete: VF config parameters are uploaded
2009/07/20-09:13:40, [LOG-1000], 225, SLOT 7 | CHASSIS, INFO, BrocadeDCX,
Previous message repeated 7 time(s)
2009/07/20-10:27:14, [CONF-1001], 226, SLOT 7 | FID 128, INFO, DCX_80,
configUpload completed successfully for VF config parameters.
Restoring logical switch configuration using configDownload
The configDownload -vf command specifies that the Virtual Fabric configuration download file is
downloaded instead of the regular configuration. After the Virtual Fabric configuration file is
downloaded, the switch is automatically rebooted.
On dual-CP platforms, if CPs are incompatible (HA not in sync), the Virtual Fabric configuration file
is not propagated to the standby CP. Otherwise, the active CP attempts to remain active after the
reboot, and the new Virtual Fabric configuration file is then propagated to the standby CP.
CAUTION
You must perform the configDownload command on the switch after restoring the Virtual Fabric
configuration to fully restore your switch or chassis configuration.
Summary of Contents for 53-1001763-02
Page 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Page 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Page 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Page 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Page 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Page 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Page 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Page 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Page 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Page 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Page 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Page 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...