Fabric OS Administrator’s Guide
53-1001763-02
McDATA-unaware features
14
McDATA-unaware features
Table 69
describes features that are unaware of M-EOS switches or fabrics and cannot be used
fabric-wide.
Table 70
describes a comprehensive matrix of feature support.
FICON and FICON CUP
Fabric Binding is required for FICON support in mixed fabrics.
Cascaded CUP and Missing Interrupt Handler Process Timeout (MIHPTO),
which should be set to 60, are supported. Cascaded CUP is only
supported in McDATA Fabric mode.
Long distance
The configure command displays the number of buffer credits allocated
to a port.
Name server
(nsShow, nsCamShow, nsAllShow)
Displays the device PID with domain offset. For example, a host attached
to a switch with domain value 1 will have a default PID of 0x61AAPP.
Zone activation
In McDATA Fabric mode, zone activations can be performed from any
switch.
In McDATA Open Fabric mode, zone activations can be performed from an
M-Series management tool, such as the Brocade Data Center Fabric
Manager (DFCM) management tool.
TABLE 68
McDATA-aware (Continued)features
Feature
Behavior
TABLE 69
McDATA-unaware features
Feature
Support
Security
ACL in strict mode
Not supported.
ACL in non-strict (Tolerant) mode,
Absent mode, and others (such as
password authentication)
Supported.
Admin Domains
Not supported.
Fabric-wide diagnostics (FC-Ping, PathInfo)
Not supported.
TABLE 70
Complete feature compatibility matrix
Feature
Support
Notes
Access Control List
•
ACL in strict mode: No
•
ACL in tolerant mode: Yes
•
ACL in absent mode: Yes
Works with SANtegrity.
Admin domains
No
Advanced Performance
Monitoring
No
Audit
Yes
Beaconing
Yes
Configuration
download/upload
Yes
Summary of Contents for 53-1001763-02
Page 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Page 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Page 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Page 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Page 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Page 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Page 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Page 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Page 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Page 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Page 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Page 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...