Fabric OS Administrator’s Guide
531
53-1001763-02
Appendix
E
Hexadecimal
Hexadecimal overview
Hexadecimal, or simply hex, is a numeral system with a base of 16, usually written using unique
symbols 0–9 and A–F, or a–f. Its primary purpose is to represent the binary code that computers
interpret in a format easier for humans to read. It acts as a form of shorthand, in which one
hexadecimal digit stands in place of four binary bits. For example, the decimal numeral 79, with the
binary representation of 01001111, is 4F (or 4f) in hexadecimal (4 = 0100, F = 1111).
Hexadecimal numbers can have either an
0x
prefix or an
h
suffix. The address 0xFFFFFA is the
same address as FFFFFA
h.
This type of address is called a hex triplet. Fibre Channel uses hexadecimal notation in hex triplets
to specify well-known addresses and port IDs.
Example conversion of the hexadecimal triplet Ox616000
Notice the PID in the nsShow output is in hexadecimal.
switch:admin> nsshow
{
Type Pid COS PortName NodeName TTL(sec)
N
610600
; 2,3;10:00:00:00:c9:29:b3:84;20:00:00:00:c9:29:b3:84; na
FC4s: FCP
NodeSymb: [36] "Emulex LP9002 FV3.90A7 DV5-5.10A10 "
Fabric Port Name: 20:08:00:05:1e:01:23:e0
Permanent Port Name: 10:00:00:00:c9:29:b3:84
Port Index: 6
Share Area: No
Device Shared in Other AD: No
Redirect: No
The Local Name Server has 1 entry }
1. Separate the triplets: 61 06 00
2. Convert each hexadecimal value to a decimal representation:
61 = Domain ID = 97
06 = Area (port number) = 06
00 = Port (ALPA) = 0 (not used in this instance, but is used in loop, shared areas in PID
assignments on blades, NPIV, and Access Gateway devices)
Result: hexadecimal triplet 610600 = decimal triplet 97,06,00
Summary of Contents for 53-1001763-02
Page 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Page 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Page 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Page 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Page 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Page 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Page 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Page 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Page 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Page 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Page 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Page 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...