Fabric OS Administrator’s Guide
33
53-1001763-02
Basic connections
2
Basic connections
Before connecting a switch to a fabric that contains switches running different firmware versions,
you must first set the same PID format on all switches. The presence of different PID formats in a
fabric causes fabric segmentation.
•
For information on PID formats and related procedures, see
Chapter 3, “Performing Advanced
Configuration Tasks”
.
•
For information on configuring the routing of connections, see
“Routing Traffic”
on page 63.
•
For information on configuring extended interswitch connections, see
“Managing Long
Distance Fabrics”
on page 441.
Device connection
To minimize port logins, power off all devices before connecting them to the switch. When powering
the devices back on, wait for each device to complete the fabric login before powering on the next
one.
For devices that cannot be powered off, first use the portDisable command to disable the port on
the switch, connect the device, and then use the portEnable command to enable the port.
Switch connection
See the hardware user’s guide of your specific switch for interswitch link (ISL) connection and cable
management information. The standard or default ISL mode is L0. ISL Mode L0 is a static mode,
with the following maximum ISL distances:
•
10 km at 1 Gbps
•
5 km at 2 Gbps
•
2.5 km at 4 Gbps
•
1 km at 8 Gbps
For more information on extended ISL modes, which enable long distance interswitch links, see
Chapter 20, “Managing Long Distance Fabrics”
.
Summary of Contents for 53-1001763-02
Page 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Page 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Page 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Page 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Page 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Page 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Page 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Page 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Page 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Page 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Page 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Page 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...