LSAN zone configuration
21
Example
sw0:admin>
fcrlsan --show -enforce
Total LSAN tags : 1
ENFORCE : enftag1
sw0:admin>
fcrlsan --show -speed
Total SPEED tags : 1
SPEED : fasttag2
sw0:admin>
fcrlsan --show -all
Total LSAN tags : 2
ENFORCE : enftag1
SPEED
: fasttag2
LSAN zone binding
LSAN zone binding is an optional, advanced feature that increases the scalability envelope for very
large metaSANs.
NOTE
LSAN zone binding is supported only on FC routers with Fabric OS v5.3.0 and later. The FC router
matrix feature is supported only on FC routers with Fabric OS v6.1.0 and later.
Without LSAN zone binding, every FC router in the backbone fabric maintains the entire LSAN zone
and device state database. The size of this database limits the number of FC routers and devices
you can have.
With LSAN zone binding, each FC router in the backbone fabric stores only the LSAN zone entries of
the remote edge fabrics that can access its local edge fabrics. The LSAN zone limit supported in
the backbone fabric is not limited by the capability of one FC router. In addition, due to the lower
LSAN count, the CPU consumption by the FC router is lower. If you configure the metaSAN such that
the backbone fabric has two groups of FC routers and there is no LSAN zone sharing and device
access between the two groups, the number of FC routers and devices supported in the backbone
fabric can be higher.
Figure 75
on page 486 shows a sample metaSAN with four FC routers in the backbone fabric.
Without LSAN zone binding, each FC router in the backbone fabric would store information about
LSAN zones 1, 2, 3, and 4.
Summary of Contents for 53-1001763-02
Page 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Page 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Page 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Page 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Page 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Page 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Page 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Page 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Page 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Page 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Page 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Page 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...