162
Fabric OS Administrator’s Guide
53-1001763-02
Policy database distribution
7
switch:admin>
fddcfg --showall
Local Switch Configuration for all Databases:-
DATABASE - Accept/Reject
---------------------------------
SCC - accept
DCC - accept
PWD - accept
FCS - accept
AUTH - accept
IPFILTER - accept
Fabric Wide Consistency Policy:- "SCC:S;DCC"
Notes on joining a switch to the fabric
When a switch is joined to a fabric with a tolerant SCC or DCC fabric-wide consistency policy, the
joining switch must have a matching tolerant SCC or DCC fabric-wide consistency policy. If the
tolerant SCC or DCC fabric-wide consistency policies do not match, the switch can join the fabric,
but an error message flags the mismatch. If the tolerant SCC and DCC fabric-wide consistency
policies match, the corresponding SCC and DCC ACL policies are compared.
The enforcement of fabric-wide consistency policy involves comparison of only the Active policy set.
If the ACL policies match, the switch joins the fabric successfully. If the ACL policies are absent on
the switch or on the fabric, the switch joins the fabric successfully, and the ACL policies are copied
automatically from where they exist to where they are absent. The Active policies set where they
exist and overwrite the Active and Defined policies where they are absent. If the ACL policies do not
match, the switch can join the fabric, but an error message flags the mismatch.
Under both conflicting conditions, secPolicyActivate is blocked in the merged fabric. Use the
fddCfg
--
fabwideset command to resolve the fabric-wide consistency policy conflicts. Use the
distribute command to explicitly resolve conflicting ACL policies.
When a switch is joined to a fabric with a strict SCC or DCC fabric-wide consistency policy, the
joining switch must have a matching fabric-wide consistency policy. If the strict SCC or DCC
fabric-wide consistency policies do not match, the switch cannot join the fabric and the neighboring
E_Ports are disabled. If the strict SCC and DCC fabric-wide consistency policies match, the
corresponding SCC and DCC ACL policies are compared.
The enforcement of fabric-wide consistency policy involves comparison of only the Active policy set.
If the ACL polices match, the switch joins the fabric successfully. If the ACL policies are absent
either on the switch or on the fabric, the switch joins the fabric successfully, and the ACL policies
are copied automatically from where they are present to where they are absent. The Active policy
set where it is present overwrites the Active and Defined policy set where it is absent. If the ACL
policies do not match, the switch cannot join the fabric and the neighboring E_Ports are disabled.
Use the fddCfg
–-
fabwideset command on either this switch or the fabric to set a matching strict
SCC or DCC fabric-wide consistency policy. Use ACL policy commands to delete the conflicting ACL
policy from one side to resolve ACL policy conflict. If neither the fabric nor the joining switch is
configured with a fabric-wide consistency policy, there are no ACL merge checks required.
The descriptions above also apply to joining two fabrics. In this context, the joining switch becomes
a joining fabric.
Summary of Contents for 53-1001763-02
Page 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Page 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Page 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Page 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Page 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Page 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Page 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Page 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Page 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Page 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Page 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Page 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...