Fabric OS Administrator’s Guide
315
53-1001763-02
E_Port authentication between Fabric OS and M-EOS switches
14
TABLE 62
Switch authentication policy-M-EOS switch with the incorrect peer secret for Fabric OS switch
If the same secret is used on both the Fabric OS switch and the M-EOS switch, it will be treated as
an incorrect secret.
Dumb switch authentication
A dumb switch refers to a switch that does not know anything about authentication. An M-EOS
switch becomes a dumb switch when it does not have the authentication feature keys enabled
(specifically the SANtegrity 1 and SANtegrity 2 feature keys). A Fabric OS switch becomes a dumb
switch when the authentication is configured to Off (See previous section for a description of Fabric
OS switch authentication Off conditions). How authentication is affected when the M-EOS switch
does not have the feature keys enabled is discussed in this section.
Table 63
on page 316 shows how authentication is affected when a Fabric OS switch is connected
to a dumb M-EOS switch.
Fabric OS
Passive
Active
On
Off
M-EOS
On
No
E_Port does not
connect
(Authentication
Rejected). When the
Fabric OS switch
generates the reject, it
disables the Fabric OS
port. When the M-EOS
switch generates the
reject, it goes to an
invalid attachment
state.
No
E_Port does not
connect
(Authentication
Rejected). When the
Fabric OS switch
generates the reject,
it disables the Fabric
OS port. When the
M-EOS switch
generates the reject,
it goes to an invalid
attachment state.
No
E_Port does not
connect
(Authentication
Rejected). When the
Fabric OS switch
generates the reject,
it disables the Fabric
OS port. When the
M-EOS switch
generates the reject,
it goes to an invalid
attachment state.
No
E_Port does not
connect
(Authentication
Rejected). When
the Fabric OS
switch generates
the reject, it
disables the
Fabric OS port.
When the M-EOS
switch generates
the reject, it
goes to an
invalid
attachment
state.
Off
Yes
Connected without any
authentication (Fabric
builds normally).
Yes*
Connected with
one-way
authentication; only
one of connected
switches performs
Authentication (Fabric
builds normally).
Yes*
Connected with
one-way
authentication; only
one of connected
switches performs
Authentication (Fabric
builds normally).
Yes
Connected
without any
authentication
(Fabric builds
normally).
Summary of Contents for 53-1001763-02
Page 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Page 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Page 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Page 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Page 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Page 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Page 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Page 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Page 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Page 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Page 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Page 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...