connection cross section solid wire
mm
2
1,0
1,5
connection cross section stranded wire
mm
2
1,0
1,5
connection cross section
AWG
18
16
power consumption
W
see P
N3
(see index entry with reference to the corresponding
page)
voltage load capacity
V
see U
N3
(see index entry with reference to the corresponding
page)
current carrying capacity “looping through” from
+24V to +24V, 0V to 0V
continuous current P
N3
/U
N3
A
6
current carrying capacity “looping through” from
+24V to +24V, 0V to 0V
inrush current I
EIN3
A
12
polarity reversal protection
within the allowed voltage range by internal protective diode
Fig.8-30:
Function, pin assignment, properties
Notes on Installation
Requirements on the connection to the 24V supply:
●
minimum cross section: 1 mm
2
●
maximum allowed inductance: 100 µH (2 twisted single strands, 75 m
long)
●
parallel line routing where possible
The control voltage supply is routed to the connection X13 from above:
266/369 Bosch Rexroth AG | Electric Drives
and Controls
Rexroth IndraDrive | Project Planning Manual
Functions and Electrical Connection Points
Summary of Contents for Rexroth lndraDrive HCS02 Series
Page 10: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 14: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 36: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 108: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 300: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 312: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 372: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 380: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...