Connection Diagram with HLB01.1D
CAUTION
Risk of damage to the device!
Establish connection from HMV_X32/8 to HLB_X32/7.
This avoids energy from the mains connection being supplied and the ZKS
stage of the DC bus resistor unit HLB being simultaneously active.
Also applies to HMV01 without integrated ZKS stage and external mains con‐
tactor HMV01.1R-W0120.
Fig.7-44:
Connection diagram HMV01 with HLB01.1D
For other connection diagrams and control circuits for the mains
connection, see the documentation “Rexroth IndraDrive - Drive
System, Project Planning Manual” in the section “Control Circuits
for the Mains Connection”