Connec‐
tion point
Type
No. of
poles
Stranded
wire
[mm²]
Description
Figure
X2
MiniDin,
female
(device)
8
0,25–0,5
serial interface
Fig.8-4:
Connections
Pin Assignment
Pin
Signal
Function
1
RTS
request to send
2
CTS
clear to send
3
TxD
transmit data
4
GND
reference potential
5
RxD
receive data
6
V
cc
supply voltage
7
n. c.
n. c.
8
n. c.
n. c.
n. c.
not connected
Fig.8-5:
Pin assignment of serial interface
Features
Feature
Unit
Min.
Typ.
Max.
number of nodes
1
allowed cable length
m
15
transmission rates
kBaud
9,6
115
connection
galvanically connected to control section
supply
allowed voltage difference be‐
tween reference potentials of
control section and data end de‐
vice
V
1
Fig.8-6:
Features
The accessory HAS05.1-005 makes available a converter from
RS232 to RS485 (see Project Planning Manual "Rexroth IndraDrive
- Drive System", chapter "Accessories").
Project Planning Manual | Rexroth IndraDrive
Electric Drives
and Controls
| Bosch Rexroth AG 247/369
Functions and Electrical Connection Points
Summary of Contents for Rexroth lndraDrive HCS02 Series
Page 10: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 14: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 36: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 108: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 300: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 312: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 372: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 380: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...