Description
Symbol
Unit
HMV01.1R-
W0018
HMV01.1R-
W0045
HMV01.1R-
W0065
HMV01.1R-
W0120
minimum distance on the top of the
device
2)
d
top
mm
300
minimum distance on the bottom of
the device
3)
d
bot
mm
130
334
temperature rise with minimum dis‐
tances d
bot
; d
top
; P
BD
ΔT
K
65
1)
HMV, HCS: plus dissipation of braking resistor, control section; KSM:
plus rated power consumption control voltage input
2) 3)
see fig. "Air intake and air outlet at drive controller"
Fig.7-34:
HMV - Data for cooling and power dissipation
Distances
CAUTION
Property damage due to temperatures higher than 105 °C!
Comply with indicated minimum distances!
A
air intake
B
air outlet
C
mounting surface in control cabinet
d
top
distance top
d
bot
distance bottom
Fig.7-35:
Air intake and air outlet at drive controller
Project Planning Manual | Rexroth IndraDrive
Electric Drives
and Controls
| Bosch Rexroth AG 209/369
IndraDrive M Supply Units
Summary of Contents for Rexroth lndraDrive HCS02 Series
Page 10: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 14: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 36: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 108: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 300: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 312: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 372: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 380: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...