Properties
Data
Unit
Min.
Typ.
Max.
number of poles
2
type
spring terminal
design
pins at device
connection cable solid wire
mm
2
0,5
1,5
connection cable stranded wire
mm
2
0,5
1,5
AWG
20
16
current load capacity
A
DC1
AC2
fuse F1
A
2
peak current when switching on
A
5
voltage load capacity
V
DC30
AC250
minimum load of contacts
mA
10
contact resistance at minimum
load
mOhm
1000
number of mechanical switching
cycles
10
6
number of switching actions at
max. time constant of load
100.000
time constant of load
ms
50
pick up delay
ms
10
drop out delay
ms
10
Fig.8-50:
Properties
Notes on Installation
Only use mains contactors with overvoltage limiter at the contactor coil (e.g.
mains contactor 3RT1456-6AP36 with overvoltage limiter 3RT1956-1CD00 by
Siemens).
8.16
X40, Acknowledge Messages of External Mains Contactor
The connection point X40 is available at HMV01.1R-W0120 with
hardware index ≥ A11; X33 does not exist at HMV01.1R-W0120.
View
Fig.8-51:
View
278/369 Bosch Rexroth AG | Electric Drives
and Controls
Rexroth IndraDrive | Project Planning Manual
Functions and Electrical Connection Points
Summary of Contents for Rexroth lndraDrive HCS02 Series
Page 10: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 14: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 36: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 108: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 300: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 312: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 372: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 380: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...