8.6.4
X5, Motor Connection HMS01.1N-W0110
View
Identifica‐
tion
Function
A1
for power connection U1 at motor
A2
for power connection V1 at motor
A3
for power connection W1 at motor
for equipment grounding conductor of motor
Terminal block
Unit
Min.
Max.
screw thread
M6
tightening torque
Nm
5,5
6,5
connection cables
stranded wire with ring cable lug
mm
2
1×16; 1×25; 1×35
2×16; 2×25; 2×35
AWG
1×6; 1×4; 1×2; 1×1
2×6; 2×4; 2×2; 2×1
occurring current load and minimum required
connection cross section
A
see technical data of device used (I
out
)
occurring voltage load
V
see technical data of device used (U
out
)
short circuit protection
A1, A2, A3 against each other and each of them against
ground
Fig.8-20:
Function, pin assignment, properties
8.6.5
X5, Motor Connection HCS03.1E-W0100…0150 and HMS01.1N-
W0150…0210
View
Identifica‐
tion
Function
A1
for power connection U1 at motor
A2
for power connection V1 at motor
A3
for power connection W1 at motor
for equipment grounding conductor of motor
Project Planning Manual | Rexroth IndraDrive
Electric Drives
and Controls
| Bosch Rexroth AG 257/369
Functions and Electrical Connection Points
Summary of Contents for Rexroth lndraDrive HCS02 Series
Page 10: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 14: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 36: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 108: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 300: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 312: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 372: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 380: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...