11.2.6
Mounting the Parts “Bar” and “End Piece” of the Accessories HAS01
The parts “bar” and “end piece” increase the current carrying capacity of the
DC bus connections by reducing the involved contact resistances.
1
bar
2
end piece (right end)
3
end piece (left end)
Fig.11-27:
Mounting bar and end piece of HAS01
●
Ad 1: Use the bars (‑042) contained in all HAS01.1-***-072‑** as shown
in the figure at L+ and L‑.
●
Ad 2 and 3: Use the end pieces contained in all HAS01.1-350-***-** and
HAS01.1-200‑***‑** at the right and left ends of the DC bus connections
in the drive system.
11.3
HAS02 Shield Connection
11.3.1
General Information
Accessories for appropriate connection of the motor cable to the drive control‐
ler, especially the shield connection of the motor cable.
There are appropriate HAS02 accessories for the different drive controllers.
Project Planning Manual | Rexroth IndraDrive
Electric Drives
and Controls
| Bosch Rexroth AG 331/369
Accessories
Summary of Contents for Rexroth lndraDrive HCS02 Series
Page 10: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 14: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 36: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 108: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 300: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 312: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 372: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...
Page 380: ...Bosch Rexroth AG Electric Drives and Controls Rexroth IndraDrive Project Planning Manual ...