5.4.2 CM-SW-01
Standard for all CSW105 compressors
The compressor module integrates the entire electronic
periphery of the compressor: It allows monitoring the
essential operating parameters of the compressor: mo-
tor and discharge gas temperature, phase and rotation
direction monitoring, oil supply and application limits
and thus protects the compressor from operation under
critical conditions. For further information, see Tech-
nical Information ST-150.
!
!
NOTICE
The compressor module may be damaged or
fail!
Never apply any voltage to the terminals of CN7
to CN12 – not even for test purposes!
The voltage applied to the terminals of CN13
must not exceed 10 V!
The voltage applied to terminal 3 of CN14 must
not exceed 24 V! Do no apply voltage to the
other terminals!
The following components are completely installed and
wired in the state of delivery:
• Slider position indicator.
• Oil monitoring (OLC-D1).
• Solenoid valves for capacity control and V
i
.
• Discharge gas temperature sensor.
• Low pressure and high pressure transmitter.
Modification to these components or their wiring is not
required and should not be done without consulting
BITZER.
The following components are not installed and wired in
the state of delivery and need to be connected:
• Motor temperature monitoring (PTC sensor in motor
winding).
• Phase monitoring (in case of a phase failure or inad-
missibly high phase asymmetry).
The compressor module internally supplies voltage to
the peripheral devices (solenoid valves, oil monitoring
device and slider position indicator) and to the terminal
strips CN7 to CN12.
Please refer to the Technical Information ST-150 for in-
formation on all connections.
5.4.3 SE-i1
This protection device with extended monitoring func-
tions can be used as an option for all HS.53 .. HS.85
compressors and CSH and CSW compressors.
Monitoring functions:
• Temperature monitoring.
• Monitoring of the PTC control circuit to detect any
short-circuit or line break/sensor failure.
• Rotation direction monitoring.
• Monitoring of phase failure and asymmetry.
• Monitoring of the maximum cycling rate.
For further information, see Technical Information
CT-110.
5.4.4 SE-E2
Optional protection device for operation with frequency
inverter and soft starter (for a ramp time shorter than
1 s).
• Dimensions and integration in the control identical to
SE-E1.
• Suitable for all CS. compressors.
• Monitoring functions are basically identical to those
of SE-E1. However, the SE-E2 monitors phase fail-
ure during the entire running time of the compressor.
For further information, see Technical Information
ST-122.
5.4.5 Monitoring of the oil circuit
• For short circuits without liquid injection (LI) for addi-
tional cooling and for small system volume and small
refrigerant charge: Indirect monitoring with oil tem-
perature sensor (standard)
!
!
NOTICE
Lack of oil leads to a too high increase in tem-
perature.
Risk of damage to the compressor!
• For circuits with liquid injection (LI) for additional
cooling and / or for great system volume as well as
parallel compounding: Monitor oil level directly with
opto-electronic oil level monitoring (option), see
chapter Opto-electronic oil level monitoring OLC-D1-
S, page 26. The connection is on the compressor
housing, see chapter Connections and dimensional
drawings, page 14, position 8.
SB-170-9
83
4 / 8
5/8-18 UNF
5
9
4 / 8
1 1/8-18 UNEF
1/8-27 NPTF
12
1 1/8-18 UNEF
295
SL
DL
J
A
355
L
70
Ø21
30
20
70
D
793
1/4-18 NPTF
6
95
225
20
450
520
F
C
I
13
M
B
1/8-27 NPTF
3 (LP)
16
7/16-20 UNF
1 (HP)
1/8-27 NPTF
2 (HP)
731
30
1/8-27 NPTF
10
11
2x M26x1,5
(Adaptor connection:
2x Ø22 / 7/8'')
15
M22x1,5
(Valve connection:
Ø12 / 1/2'')
Fig. 11: Croquis coté CSH9553-180(Y) .. CSH95113-320Y
A
mm
B
mm
C
mm
D
mm
F
mm
I
mm
J
mm
L
mm
M
mm
CSH9553 .. CSH9573
1824
717
776
224
417
746
930
744
106
CSH9583-210Y,
CHS9593-240Y
1842
717
776
242
417
764
948
751
113
CSH9583-280(Y),
CSH9593-300(Y)
1869
717
776
269
417
791
975
751
113
CSH95103-280Y
1955
731
796
269
431
791
975
758
113
CSH95103-320(Y),
CSH95113-320Y
1975
731
796
289
431
810
995
758
113
Рис. 11: Чертежи с указанием размеров для компрессоров CSH9553-180(Y) .. CSH95113-320Y
(Присоединение для
клапана: Ø12 / 1/2")
(Присоединение для
адаптера: 2x Ø22 / 7/8")