SB-170-9 RUS
85
SB-170-9
25
5.4.2 CM-SW-01
Standard for all CSW105 compressors
The compressor module integrates the entire electronic
periphery of the compressor: It allows monitoring the
essential operating parameters of the compressor: mo-
tor and discharge gas temperature, phase and rotation
direction monitoring, oil supply and application limits
and thus protects the compressor from operation under
critical conditions. For further information, see Tech-
nical Information ST-150.
!
!
NOTICE
The compressor module may be damaged or
fail!
Never apply any voltage to the terminals of CN7
to CN12 – not even for test purposes!
The voltage applied to the terminals of CN13
must not exceed 10 V!
The voltage applied to terminal 3 of CN14 must
not exceed 24 V! Do no apply voltage to the
other terminals!
The following components are completely installed and
wired in the state of delivery:
• Slider position indicator.
• Oil monitoring (OLC-D1).
• Solenoid valves for capacity control and V
i
.
• Discharge gas temperature sensor.
• Low pressure and high pressure transmitter.
Modification to these components or their wiring is not
required and should not be done without consulting
BITZER.
The following components are not installed and wired in
the state of delivery and need to be connected:
• Motor temperature monitoring (PTC sensor in motor
winding).
• Phase monitoring (in case of a phase failure or inad-
missibly high phase asymmetry).
The compressor module internally supplies voltage to
the peripheral devices (solenoid valves, oil monitoring
device and slider position indicator) and to the terminal
strips CN7 to CN12.
Please refer to the Technical Information ST-150 for in-
formation on all connections.
5.4.3 SE-i1
This protection device with extended monitoring func-
tions can be used as an option for all HS.53 .. HS.85
compressors and CSH and CSW compressors.
Monitoring functions:
• Temperature monitoring.
• Monitoring of the PTC control circuit to detect any
short-circuit or line break/sensor failure.
• Rotation direction monitoring.
• Monitoring of phase failure and asymmetry.
• Monitoring of the maximum cycling rate.
For further information, see Technical Information
CT-110.
5.4.4 SE-E2
Optional protection device for operation with frequency
inverter and soft starter (for a ramp time shorter than
1 s).
• Dimensions and integration in the control identical to
SE-E1.
• Suitable for all CS. compressors.
• Monitoring functions are basically identical to those
of SE-E1. However, the SE-E2 monitors phase fail-
ure during the entire running time of the compressor.
For further information, see Technical Information
ST-122.
5.4.5 Monitoring of the oil circuit
• For short circuits without liquid injection (LI) for addi-
tional cooling and for small system volume and small
refrigerant charge: Indirect monitoring with oil tem-
perature sensor (standard)
!
!
NOTICE
Lack of oil leads to a too high increase in tem-
perature.
Risk of damage to the compressor!
• For circuits with liquid injection (LI) for additional
cooling and / or for great system volume as well as
parallel compounding: Monitor oil level directly with
opto-electronic oil level monitoring (option), see
chapter Opto-electronic oil level monitoring OLC-D1-
S, page 26. The connection is on the compressor
housing, see chapter Connections and dimensional
drawings, page 14, position 8.
SB-170-9
85
257
513
572
114
540
1353
250
534
50
50
261
457
1/8-27 NPTF
6
33
M10x1,5
10
550
108
135
Ø17
120
33
305
360
308
292
616
1/8-27 NPTF
3 (LP)
O
N
20
I1
I2
1/8-27 NPTF
2 (HP)
13
Ø22 (7/8'')
17
43
SL
DL
14
1/8-27 NPTF
1 (HP)
5
9
4
1/8-27 NPTF
12
1 1/8-18 UNEF
4 / 8
1 1/8-18 UNEF
5/8-18 UNF
M22x1,5
(Adaptor connection:
Ø16 / 5/8'')
Fig. 13: Croquis coté CSW7573-60Y .. CSW7593-90(Y), CSH7673-70Y .. CSH7693-90Y
I1
mm
I2
mm
N
mm
O
mm
CSW7573, CSH7673
153
258
20
70
CSW7583, CSW7593, CSH7683, CSH7693
157
261
23
70
Représentation avec la vanne ECO en option (position
13).
Légende pour les raccords voir tableaux 8, page 89.
Рис. 13: Чертежи с указанием размеров для компрессоров CSW7573-60Y .. CSW7593-90(Y), CSH7673-70Y .. CSH7693-90Y
Изображение с опциональным ECO-клапаном
Условные обозначения для присоединений
(позиция 13).
смотрите втаблице 8, стр. 89.
(Присоединение для
адаптера: Ø16 / 5/8")