10-14
User Guide for the Avaya P580 and P882 Multiservice Switches, v6.0
Chapter 10
CAUTION:
Active and Standby Roles
shows possible supervisor configurations and, for each
configuration, which supervisor is active and which is standby.
* Note: If the standby supervisor becomes active, it assumes the IP and
MAC addresses of the previously active supervisor.
* Note: When a standby supervisor is installed in the switch there is a
45-second wait period before the standby supervisor is fully
initialized.
Do not remove the standby supervisor module during initialization.
Table 10-1. Supervisor Module Configurations
Configuration
Active and Standby Role
One supervisor in slot 1
The slot 1 supervisor module is active.
If a supervisor module is inserted into slot 2, the slot
1 supervisor module remains active and sends health
reports to the standby supervisor in slot 2.
One Supervisor module
in slot 2
The slot 2 supervisor module is active.
If a supervisor module is inserted into slot 1, the slot
2 supervisor module remains active and sends health
reports to the standby supervisor in slot 1.
If the slot 2 supervisor is removed, reset, or fails, or if
the switch is reset, the slot 1 supervisor becomes the
active supervisor, and the slot 2 supervisor becomes
the standby. The slot 1 supervisor then sends health
reports to the slot 2 standby supervisor.
Supervisor modules in
slot 1 and slot 2
The slot 1 supervisor module is active and sends
health reports to the standby supervisor in slot 2.
If the slot 1 supervisor module is removed, reset, or
fails, the slot 2 supervisor becomes the active
supervisor. If you then replace the slot 1 supervisor, it
remains the standby supervisor and receives health
reports from the active supervisor in slot 2.
If the slot 2 supervisor is removed, reset, or fails, or if
the switch is reset, the slot 1 supervisor becomes the
active supervisor, and the slot 2 supervisor becomes
the standby. The slot 1 supervisor then sends health
reports to the slot 2 standby supervisor.
Note:
If the switch is reset, slot 1 supervisor is the
active supervisor, unless it has failed.
Summary of Contents for Cajun P580
Page 26: ...xxvi User Guide for the Avaya P580 and P882 Multiservice Switches v6 0 Preface...
Page 50: ...1 24 User Guide for the Avaya P580 and P882 Multiservice Switches v6 0 Chapter 1...
Page 158: ...5 24 User Guide for the Avaya P580 and P882 Multiservice Switches v6 0 Chapter 5...
Page 308: ...10 18 User Guide for the Avaya P580 and P882 Multiservice Switches v6 0 Chapter 10...
Page 508: ...16 26 User Guide for the Avaya P580 and P882 Multiservice Switches v6 0 Chapter 16...
Page 530: ...18 14 User Guide for the Avaya P580 and P882 Multiservice Switches v6 0 Chapter 18...
Page 622: ...21 22 User Guide for the Avaya P580 and P882 Multiservice Switches v6 0 Chapter 21...
Page 652: ...23 20 User Guide for the Avaya P580 and P882 Multiservice Switches v6 0 Chapter 23...
Page 660: ...24 8 User Guide for the Avaya P580 and P882 Multiservice Switches v6 0 Chapter 24...
Page 714: ...25 54 User Guide for the Avaya P580 and P882 Multiservice Switches v6 0 Chapter 25...
Page 728: ...Appendix B B 4 User Guide for the Avaya P580 and P882 Multiservice Switches v6 0...