400 Series Installation and Configuration
RP 410 Remote Panel Installation
91
Type the password to get access to the submenu.
Note! The factory default password is 1234. If this
password does not work, a new password has been set.
Lost Password
The RP will issue an encrypted code if a wrong password
is entered.
This encrypted code can be sent to your distributor, who
will be able to obtain the original password.
Change Password
The default password is 1234.
In order to preserve the configuration from unauthorized
access, the password should be changed. Enter a 4-digit
code to secure the configuration, and keep the password
in a safe place.
Station Priority
Different priorities are used in conjunction with multiple
RP remote panels. If only one RP is installed, the priority
should be set to 1.
Society regulations require that only one remote panel
can control an engine, at any given time.
In the RP, the panel currently controlling an engine is
called the Active Station for that engine.
There are three RP priorities.
Priority 1 panels will always become an active
station if required. It will take the engine control
from panels with priority 1, 2 or 3.
Priority 2 panels must ask for engine control.
Priority 1 and Priority 2 panels with engine control
must agree to the handover.
Priority 3 panels can never do engine commands.